Product Description

Product Features


The mining flowmeter, high-precision anti-interference mining intrinsically safe ultrasonic flowmeter YHL500 is suitable for liquid measurement of various pipe diameters. The larger the pipe diameter, the higher the measurement accuracy. It can achieve bidirectional flow measurement with no pressure loss and is not affected by changes in gas quality, liquid state, pressure, temperature, gas, and other composition variations. The signal reception of the mining ultrasonic flowmeter system is fully digitalized, allowing each pulse to be compared with preset standards to detect signal quality, thereby obtaining high-quality measurement results.

Detailed Introduction


For details of the mining flowmeter, high-precision anti-interference mining intrinsically safe ultrasonic flowmeter YHL500, please contact WeChat: 1/5*0/5-3*7/5*3-6*2/8


The mining flowmeter, high-precision anti-interference mining intrinsically safe ultrasonic flowmeter YHL500 is suitable for liquid measurement of various pipe diameters. The larger the pipe diameter, the higher the measurement accuracy. It can achieve bidirectional flow measurement with no pressure loss and is not affected by changes in gas quality, liquid state, pressure, temperature, gas, and other composition variations. The signal reception of the mining ultrasonic flowmeter system is fully digitalized, allowing each pulse to be compared with preset standards to detect signal quality, thereby obtaining high-quality measurement results.

 

The installation position of the mining flowmeter, high-precision anti-interference mining intrinsically safe ultrasonic flowmeter YHL500 has a significant impact on measurement accuracy. The selected pipe section should avoid interference and eddy currents, which are two major factors affecting measurement accuracy. Generally, the selected pipe section should meet the following conditions:

 

● The fluid should fill the pipe;

● Avoid installing the device near water pumps, high-power radio stations, frequency converters, i.e., in areas with strong magnetic fields and vibration interference.

● The upstream distance from the installation point to the water pump should be 30D.

● Choose pipe material that is uniform and dense, and easy for ultrasonic transmission;

● There should be sufficient straight pipe section. The upstream straight pipe section at the installation point must be greater than 10D (Note: D = diameter), and the downstream should be greater than 5D.

● There should be enough space around the pipe for on-site personnel to operate.

 

Before installing the mining flowmeter, high-precision anti-interference mining intrinsically safe ultrasonic flowmeter YHL500 clamp-on ultrasonic flowmeter, the following issues should be noted:

 

● The distance from the sensor installation point to the host.

● The temperature of the medium.

● Whether the power supply voltage is stable;

● Whether there are interference sources at the installation site.

● The type of fluid, whether it contains impurities, bubbles, and whether it is full pipe.

● Pipe material, wall thickness, and diameter.

● Whether the host placement area is at a constant temperature.

● Whether remote signal transmission is needed and the type;

 

Jining Huarui Automation Technology Co., Ltd. is a manufacturer of mining sensors integrating research and development, production, and sales. After more than ten years of development, the company's main products currently include the mining intrinsically safe ultrasonic flowmeter YHL500, mining intrinsically safe ultrasonic level gauge GUC8, mining submersible level gauge GUY10, mining temperature inspection instrument ZCW8-Z, mining radar level meter GUL30, GUL60, GUL70, and a series of mining measurement products such as passive online ash analyzer. The products are widely used in different industries such as coal, cement, and steel. The company has R&D department, production department, engineering technology department, sales department, and flow calibration device workshop. The company's professional technicians have rich underground work experience and on-site experience, and a strong technical team is a solid guarantee for product quality. We have focused on the research, development, and production of sensors for 11 years, striving for excellence and strict quality control, providing customers with high-quality mining instruments through meticulous and comprehensive services.

 

 





WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio Tester、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us