Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

Mining Ultrasonic Flowmeter Insertion Mining Flow Sensor

Published: 2024-10-21 19:50:02

Views: 2922

Category: Mining Multi-functional Control Console

Product Description

Product Features


The YHL500 mining intrinsically safe ultrasonic flow sensor is a mining intrinsically safe device. The mining intrinsically safe ultrasonic flowmeter has a very simple installation method, no need to break pipes, no need to stop water, allowing customers to easily achieve flexible pipeline flow measurement. The product can also be equipped with installation fixtures, requiring no daily maintenance, and providing reliable, accurate, drift-free measurement for a long time.

Detailed Introduction


YHL500 mining intrinsically safe ultrasonic flow sensor details micro power 1/5*0-5*3/7*5-3*6/2*8


The YHL500 mining intrinsically safe ultrasonic flow sensor is a mining intrinsically safe device. The mining intrinsically safe ultrasonic flowmeter has a very simple installation method, no need to break pipes, no need to stop water, allowing customers to easily achieve flexible pipeline flow measurement. The product can also be equipped with installation fixtures, requiring no daily maintenance, and providing reliable, accurate, drift-free measurement for a long time.

 

The flow sensor adopts advanced digital correlation technology and intelligent adaptive acoustic wave technology, using the "40 picosecond time difference measurement method" as the principle to measure the flow rate of liquid in circular pipes. The product has reached advanced levels both domestically and internationally, and can be installed in coal mines, industrial and mining enterprises, and other places. The ultrasonic flowmeter has strong anti-interference capability. It is insensitive to clutter signal interference caused by pipeline vibration. For places with short straight pipe sections, the fluid itself is highly disturbed, and the received signal is complex. Therefore, in pump rooms, as long as it has a very short straight pipe section (3-5 times the pipe diameter), it can obtain stable readings.

 

The mining intrinsically safe ultrasonic flowmeter should pay attention to the following aspects of influence:

 

1. Influence of installation environment

 

When installing the ultrasonic flowmeter, it is generally required that the upstream and downstream of the flowmeter have straight pipe sections of 10 times and 5 times the pipe diameter respectively, to ensure that the flow state of the measured medium meets the instrument accuracy requirements. During on-site installation and use, it is often impossible to find an installation position that meets the requirements. Insufficient straight pipe sections lead to different measurement errors. The downstream straight pipe has a smaller impact on accuracy. When there is a straight pipe of more than 3 times the pipe diameter upstream, it can basically meet the use requirements. When the upstream straight pipe section is insufficient, such as when installing after elbows, valves, or pump valves, it generally shows positive errors.

 

2. Influence of pipeline parameter input

 

After the ultrasonic flowmeter is installed, parameters such as pipe diameter and wall thickness need to be input. When the pipeline is fixed and the input parameters are changed, the error in pipe diameter input will double the error in measurement results. The input error of wall thickness is positively correlated with the measurement error, but it does not have a significant impact on the measurement results.

 

3. Influence of lining and pipe material

 

4. Sensor installation

 

5. Other external factors, coupling agent, signal cable

 

After years of development, our company mainly has GUL30, GUL60 mining intrinsically safe radar level sensors, GUL70 mining intrinsically safe radar level instruments, GUL60(H) mining intrinsically safe radar level instruments, HRRD purge-type radar level instruments, HRRD70 intrinsically safe radar level meters, YHL500 mining intrinsically safe ultrasonic flowmeters, GUC8 mining intrinsically safe ultrasonic level gauges, GUY10 mining input-type liquid level sensors, GWP200 mining intrinsically safe temperature sensors, and ZCW8-Z mining flameproof and intrinsically safe temperature inspection devices, and other products suitable for multiple industries and multiple uses.




WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio Tester、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us