The ARS-SF10 moisture meter for insulating paper in power plants, produced by Shenzhen Airis, is widely used for moisture determination in the production process of coated paper, copy paper, fax paper, newsprint, white cardboard, coated board, corrugated paper, kraft paper, linerboard, pulp board, cartons, corrugated cardboard, white board, writing paper, newsprint, tracing paper, cartons, paperboard, pulp, and waste paper.

Detailed Introduction


The ARS-SF10 moisture meter for insulating paper in power plants produced by Shenzhen Airis adopts the traditional classical physical moisture detection method (oven drying method), combining a load cell and infrared radiation source to measure the moisture content of samples in real time. The ring-shaped infrared heating source rapidly dries the sample; during the drying process, the infrared moisture meter continuously measures and instantly displays the weight loss of the sample and derives the moisture content. Parameters and conditions can be set directly through the 5-inch touch LCD screen, achieving human-machine integrated operation. Compared with the international oven heating method, the Airis moisture meter can quickly and uniformly dry samples at high temperatures without damaging the sample surface. Generally, results can be obtained within a few minutes and the value is automatically locked, requiring no personnel supervision. The results are consistent with oven experiments, making it a new type of rapid detection instrument. The principle of the Airis paper products moisture meter meets the GB/T29249-2012 electronic weighing drying method moisture meter.

Product Features

1. No installation, debugging, or training required; ready to use after unpacking

2. Simple operation, one-key operation, automatic shutdown, and quick acquisition of moisture and other values

3. The heat dissipation unit adopts an aluminum alloy integrated molded heat dissipation panel, which absorbs excess heat and effectively dissipates it

4. Visual transparent front window design, beautiful and elegant, allowing real-time observation of moisture changes during operation

5. Multiple data display modes: moisture value, initial sample weight, final sample weight, measurement time, initial temperature, final temperature

6. Imported materials and components ensure instrument stability and long service life, which is our eternal pursuit

7. New appearance design, integrated molding with special formula of imported raw materials, truly high-temperature resistant

8. Unique windproof design and anti-electromagnetic radiation design protect the stability of the weighing system

9. RS232 serial port printer communication

10. Imported electromagnetic force sensor for higher stability and resistance to temperature drift

Technical data of ARS-SF10 moisture meter for insulating paper in power plants:

Model

ARS-SF10

ARS-SF20

ARS-SF50

Weighing capacity

110g

110g

110g

Display readability

0.001g

0.002g

0.005g

Readability

(sample >10g)

0.01%

0.02%

0.05%

Repeatability precision:

±0.01%

±0.02%

±0.5%

Heating source

Ring halogen lamp

Display screen

5-inch LCD eye-protection touch screen

Temperature setting

Room temperature - 160℃

Weight calibration

External calibration

Result display

Weight before drying, weight after drying, end mode, remaining heating time (min), heating temperature, moisture loss rate, drying rate, wet weight rate, moisture regain rate

Communication interface

Thermal printing (direct printing of test data)

Standard RS232 communication interface, can connect to printer, PC, and other peripherals

Pan size

Φ90 (mm)

Net weight

3.2kg

Gross weight

4.6kg

Precautions:

1. The Airis rapid moisture meter is used to measure the moisture content in samples. Any other use may cause personal injury and damage to the instrument.

2. Please read the manual carefully before use. Do not use under environmental conditions that do not meet the requirements.

3. Ensure sufficient space around the instrument to avoid heat accumulation and overheating.

4. Since the area around the heating unit becomes hot, do not place flammable items near the instrument.

5. After the test, the sample itself, the heating unit, and its container may still be very hot. Be careful when removing the sample.

6. During the heating and drying process, the ring heating element can reach 400℃. Do not open or touch the heating unit. If it needs to be opened, disconnect the power and wait until it cools down.

7. For matrices containing toxic elements, such matrices can only be heated and dried under well-ventilated conditions.

Operating steps:

① Evenly place the sample to be tested into the sample pan

② Cover with the heating cover

③ Press the "Start" button and the instrument will automatically complete the process. After measurement, the instrument automatically alarms, and the measurement result is locked on the LCD screen.




WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio Tester、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us