Dali Electric recommends for you
◆ Adopts a beautiful and generous PVC panel
◆ Directly displays the primary current, convenient for test observation and recording.
◆ High measurement accuracy 0.2 class
◆ High power, small size, strong load capacity
◆ Small size, light weight, only 30% to 70% of similar products, very convenient to carry.
4. Operation aspects
(1) After wiring, check once to see if there are any wiring errors and whether the connectors are in good contact.
(2) During the test, if there is arcing, or any abnormal phenomena such as no display when starting up, immediately turn off the power and recheck the wiring.
(3) In actual wiring, the current output terminal should form a loop, otherwise the instrument will not output current.
(4) This current generator comes with random output wires; the external copper conductor should be selected according to 10A/mm2. (Standard configuration is two 3-meter test leads)
(5) The capacity of this equipment is designed for short-term operation of 5 minutes. If used for batch testing, the working time should be less than 2.5 minutes, and wait for 10 minutes before the next operation. For temperature rise tests (30 minutes to 24 hours), it should be configured according to long-term working temperature rise.
High Current Generator 1000A
1. Maximum output DC current value: 5000A, can work continuously for 8 hours at this current.
2. Maximum output DC voltage value: 5V.
3. Output current adjustment method: 0~5000A continuously adjustable.
AC: 0-5000A DC: 0-5000A
4. Accuracy requirements:
Source effect: ≤0.3% of rated value
Time drift: ≤1% of rated value
Temperature drift: ≤0.04% of rated value/℃
Load effect: ≤1% of rated value (only the output voltage change rate caused by the output current changing from zero to rated value)
Ripple voltage: ≤1% of rated value + 10mV.
5. Line regulation: 0.1%
Load regulation: 0.1%
6. Output display:
Display method: Voltage meter is 4-digit digital display
Current meter is 5-digit digital display
Display accuracy: Voltage meter 0.1V
Current meter 0.1A
Display error: Voltage meter ≤0.2%±1 digit
Current meter ≤0.2%±1 digit
7. The equipment should have automatic protection against overvoltage, overcurrent, overtemperature, phase loss, etc.

Note: The above information and technical parameters are compiled and released by Yangzhou Dali Electric Co., Ltd.