A power outage occurred in Chongming Residential Area, Dachaidan Administrative Committee, Haixi Prefecture, Qinghai Province. After receiving the repair request, Xiong Guoxi, the head of the distribution network operation and inspection class of State Grid Dachaidan Power Supply Company, immediately organized repair personnel to rush to the scene. They split into three groups to conduct fault investigation and locate the fault point. One group inspected the transformer in the station area, another patrolled the 10kV Keqi Road, and the third group conducted interviews near the site.
“Line inspection completed, everything is normal.”
“Buildings 3 and 4 of Chongmin Residential Area in the 01 Oil Station area are missing a phase.”
“It should be a problem with the power supply cables for Buildings 3 and 4.” Based on years of work experience, Xiong Guoxi immediately determined. The repair personnel used a cable fault tester to locate the faulty cable.
At 17:24, the repair personnel identified the fault point: due to continuous rainfall, the cable became damp and caused a short circuit. “The original cable is no longer usable. Immediately change the work plan and lay a new cable for power supply.” Xiong Guoxi said, “The cable is directly buried, so to replace it, the foundation must be fully excavated.”
“How long until the power is back? We have guests at home tonight!”
“Yes, we can't delay the children's studies...” Because of the power outage, residents of the community gradually gathered around the repair personnel. Everyone spoke up, making the repair team feel even more urgency to speed up the repair.
“Everyone, please go back. We guarantee to repair it as quickly as possible. Sorry for the inconvenience.” Xiong Guoxi explained to the residents.
In order to minimize the power outage time and quickly restore power supply, the repair personnel performed their respective duties and engaged in the emergency repair in an orderly but busy manner. Those responsible for the site began digging trenches, those responsible for materials returned to the company to find cables of the same model. Once everything was ready, they skillfully began making cable joints, squatting or standing for about an hour at a time.
As night fell, the onlookers had long dispersed. Under the emergency lighting, the repair personnel were busy repairing the damaged cable, stripping the sheath, cleaning, installing copper tubes, crimping, applying insulation layers, baking, debugging... During the repair process, each repair personnel maintained a high level of concentration, carefully executing every production instruction. No one complained of fatigue or hardship... until the withstand voltage test was completed.
At 23:32, lights turned on one by one in the night, and Chongming Residential Area had its power restored.