Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

SMG2000B Dual-Clamp Phase Voltmeter - Yangzhou DARUI Co., Ltd.

Published: 2020-08-12 10:23:52

Views: 2922

Category: Mining Multi-functional Control Console

Product Description

SMG2000B Dual-Clamp Phase Voltmeter



DARUI Electric recommends



Adopts clamp-type current transformer for input of measured current, thus no need to disconnect the circuit under test. When measuring phase between U1-U2, the two input circuits are completely isolated, avoiding possible short circuits caused by miswiring that could damage the meter. The display uses a high-contrast LCD with characters up to 25mm, and the screen angle can be freely adjusted about 70° for optimal viewing.

    The meter housing is made of engineering insulating material, equipped with a rubber shockproof protective cover, safe and reliable.



SMG2000B Dual-Clamp Phase Voltmeter



Product Parameters



1. Basic Error

1.1 Reference Working Conditions

    Ambient temperature: (23±5)℃.

    Ambient humidity: (45~75)% RH.

    Measured signal waveform: sine wave, β=0.02.

    Measured signal frequency: (50±0.2)Hz.

    Position of the current-carrying conductor in the clamp: arbitrary.

    Measured signal amplitude range when measuring phase: 100~220V, 0.5A~1.5.

    External reference frequency electromagnetic field interference: should be avoided.

1.2 Basic Error Limits

1) AC voltage (see Table 1):





























Table 1: AC voltage measurement error
Range Resolution Basic error limit
20V 0.01V ±(1.2%RD+2)
200V 0.1V ±(1.0%RD+2) 
500V 1V ±(1.2%RD+2) 


    Input impedance: 2MΩ for all ranges.

2) AC current (see Table 2):



























Table 2: AC current measurement error
Range Resolution Basic error limit
200mA 0.1mA ±(1.0%RD+2)
2A 1mA
10A 10mA


3) Phase U-U, U-I, I-I (see Table 3):





















Table 3: Power frequency phase measurement error
Range Resolution Basic error limit
0~360° 1° ±3°


    When measuring U1-U2 phase, the voltage input circuit impedance: 40KΩ.



2. Operating Error

2.1 Rated Working Conditions:

    Ambient temperature: (0~40)℃.

    Ambient humidity: (20~80)% RH.

    Measured signal waveform: sine wave, β=0.05.

    Measured signal frequency: (50±0.5)Hz.

    Position of the current-carrying conductor in the clamp: arbitrary.

    Measured signal amplitude range when measuring phase:

    When measuring U1-U2 phase: 30V~500V;

    When measuring I1-I2 phase: 10mA~10.00A;

    When measuring U1-I2 or I1-U2 phase: 10V~500V, 10mA~10.00A.

    External reference frequency electromagnetic field interference: should be avoided.

2.2 Rated Working Error Limits:

    Under the rated working conditions described in 2.1, the rated working error limits of each measured quantity shall not exceed twice the corresponding basic error limits.



3. Other Technical Characteristics

3.1 Display digits: 3 1/2 digits.

3.2 Sampling rate: 3 times/second.

3.3 Power supply: single 9V laminated battery, power current less than 5mA.

3.4 Dimensions:

    Meter body: 192mm×95mm×55mm;

    Clamp body: 140mm×42mm×20mm;

    Claw opening: Φ7mm×9mm.

3.5 Weight:

    Meter body: 280g;

    Measuring clamps: 2×200g.

3.6 Storage conditions:

    Temperature: -10℃~50℃. 











Note: The above information and technical parameters are compiled and released by Yangzhou DARUI Electric Co., Ltd.

 


WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio Tester、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us