Variable Frequency Anti-Interference Ground Grid Earth Resistance Tester - Yangzhou Darui

Variable Frequency Anti-Interference Ground Grid Earth Resistance Tester - Yangzhou Darui

Darui Electric recommends to you

Variable Frequency Anti-Interference Ground Grid EarthResistance Testeradopts electronic countermeasure digital filtering technology, with extremely strong anti-interference capability. (Key performance)

The frequency selection characteristic is sharp, with a passband of ±0.3Hz. The error caused by a measured 200V interference at ±1Hz offset frequency measurement is less than 0.1mV, and the interference suppression capability reaches more than 1/10000, far exceeding the anti-interference capability of some imported instruments at a few percent, ensuring test accuracy. The system also has an additional 50Hz notch filter designed to completely filter out 50Hz power frequency interference.

☆The system has large output power (2-20KW), high voltage (0-1000V), and large output current (0-50A).

It completely solves the problems of similar equipment having small output power and voltage, making it difficult to generate current on site. Most current ground grid measurement equipment has relatively small power, such as common equipment with output of 100V/5A (500W) or 150V/10A (1500W). Due to the small output power and voltage, it is often difficult to generate sufficient current on site, and in practice, the test current (such as 5A) as stated on the equipment nameplate cannot be achieved. In many cases, the measured signal becomes very small and difficult to measure accurately. The high-power (5-20KW) signal source of this system can ensure sufficient loop current, improve the signal-to-noise ratio, and accurately measure small quantities such as contact voltage and step voltage.

☆Point-by-point step precise frequency selection test, not the less accurate dual-point frequency conversion.

This system uses a 40-70Hz step 1Hz multi-point frequency conversion test, overcoming the limitations of the dual-point frequency conversion method, thus obtaining the frequency characteristics of the grounding system. It can clearly discover and eliminate bad measurement values caused by same-frequency harmonic interference, making the measurement results more consistent with actual values. Some instruments, limited by technology, use low-precision simple LC filter circuits plus simple software processing, selecting dual-point frequency conversion far from the power frequency (such as 40/60Hz). Their anti-interference effect, measurement accuracy, and data repeatability need to be verified, and they may be affected by specific frequency interference signals. Dual-point frequency conversion measurement is not an ideal method for anti-interference measurement of ground grids.

☆Can accurately measure grounding impedance, step potential difference, contact potential difference, soil resistivity, surface potential distribution of the field area, and current distribution of the ground grid and other parameters.

☆Simultaneously measures the voltage and current at a specified frequency, and the phase difference between voltage and current, automatically calculating the grounding impedance and its resistive and reactive components.

☆Has an independent high-precision frequency-selective voltmeter with built-in human body simulation resistance, making it convenient to measure step voltage and contact voltage.

☆Automatic range conversion. Uses advanced gain programming amplification technology to ensure measurement accuracy in both high and low range, without manual gear shifting, simple and convenient.

☆Each range can be calibrated separately, ensuring accuracy.

☆High-stability variable frequency source with pure sine wave output ensures the equivalence of test results, and has overvoltage, overcurrent, and overheat protection functions.

☆Large screen displays test data, one-key mouse-style knob, foolproof operation.

☆Can save more than 2000 sets of data, upload data to a computer for analysis and processing. Comes with an SD data storage card for convenient data download.

☆Built-in rechargeable battery, can work continuously for more than 8 hours.

1-20092PQ154630.jpg

Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.





← Previous
Ground Grid Earth Resistance Tester - Yangzhou DARUI
Next →
Lightning Protection Detection Ground Grid Earth Resistance Tester - Yangzhou Darui
WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio Tester、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us