Instrument Details




The CEL-630 is available in four models: CEL-630, CEL-631, CEL-632, and CEL-633. These four models can also have suffixes added to represent different configuration requirements.

UK Casella CEL-630 Recording Octave Band Noise Analyzer Product Introduction:

UK Casella CEL-630 Series Model Selection

The CEL-630 is available in four models: CEL-630, CEL-631, CEL-632, and CEL-633. These four models can also have suffixes added to represent different configuration requirements

A represents broadband

B represents octave band

C represents 1/3 octave band

Among them, the CEL-630A series can be further specified with a level, such as CEL-630A1 or CEL-630A2, where "1" represents Level 1 and "2" represents Level 2. Each instrument comes with a standard kit, wind shield, and calibration certificate.


The CEL-630 is easy to use and designed to meet the measurement requirements for workplace and environmental noise. It complies with the latest IEC and ANSI international standards for sound level meters. Users simply power on the instrument, and it automatically calibrates and begins measuring according to the preset configuration. Regardless of the preset measurement parameters, the CEL-630 measures all data and saves it simultaneously, so errors are avoided.
The CEL-630 sound level meter uses the latest digital technology with a single measurement range, eliminating the need to adjust the measurement range and ensuring high performance across all noise sources. It can be used for environmental and/or occupational noise spectrum analysis, as well as advanced features such as data marking, timers, and historical data logging. The CEL-630 series is advanced yet easy to use.
Recording is a basic function of the CEL-630; all models can perform voice recording. Users can speak into the microphone before and after measurements to annotate results, eliminating the need for manual notes. During measurement, data can be "marked," which also allows for recording of abnormal or important events and audio for later noise source identification. If the instrument is used unattended, recording can be triggered by a condition, such as exceeding a certain level for a period of time. In such cases, additional data is collected along with the audio. This is especially important when noise sources are transient.



UK Casella CEL-630 Recording Octave Band Noise Analyzer Main Functions:

* Ideal for environmental or occupational noise monitoring
* Power-on-and-run functionality for ease of use
* Latest digital technology with high-resolution color TFT display
* Pre-configured for occupational and environmental measurements
* Voice annotation for measurements
* Single measurement range up to 140dB, no range adjustment needed
* Data marking, back-erase function, and recording
* Level-triggered events for transient measurements
* Real-time octave band and 1/3 octave band measurements
* Simultaneous measurement of all parameters with frequency and time weightings
* Available in Class 1 or Class 2 models
* 2GB memory can store over a year of data
* Detachable preamplifier
* Outdoor environmental kit available

UK Casella CEL-630 Recording Octave Band Noise Analyzer Main Applications:
Occupational Noise Measurement:
Workplace noise assessment according to ISO9612
Hearing protection
Noise exposure measurement
Ensuring compliance with workplace noise regulations
Environmental Noise Measurement:
Boundary noise assessment
Noise nuisance complaints
Measurements according to ISO1996, BS4142
Construction considerations





Instrument Parameters



We will strive to translate and edit according to the original technical specifications. In case of any differences between Chinese and English technical parameters, the English parameters shall prevail.

UK Casella CEL-630 Recording Octave Band Noise Analyzer Technical Specifications:
Standards Compliance: IEC61672: 2002 Class 1 and 2, IEC 60651: Type 1 and 2 (1979),
IEC60804: Type 1 and 2 (2000), ANSI S1.4: Type 1 and 2 (1983)
Filters: IEC61260: Class 0, ANSI S1.43: (1996)
Measurement Range: 20-140dB RMS (143.3dB peak)
Inherent Noise: 19dB(A) Class 1, 25dB(A) Class 2
Time Weighting: F, S, I simultaneously
Frequency Weighting: A, C, and Z
Frequency Bands: 11 octave bands 16Hz-16kHz (B & C modes only), 33 1/3 octave bands 12.5Hz-20kHz (C mode)
Amplitude Weighting (Q): 3, 4, and 5 simultaneously
Erase Data: Last 10 seconds in accumulation mode
Timer: 1s-24h, timed on/off: 6 programmable and repeatable
Memory: 1GB. (When set to 1s logging interval, can record over 2.5 years, 999 measurement sets) All features accessible via Casella Insight software
Battery: 3x AA alkaline batteries, 10-15 hours continuous use (with backlight on)
External Power: 9-14V DC 150mA
Tripod: 1/4" standard thread
Operating Humidity: 5 - 90% (non-condensing)
Operating Temperature: -10~+50 C (Class 1), 0~+40 C (Class 2)
Atmospheric Pressure: 65~108kPa.


UK Casella CEL-630 Recording Octave Band Noise Analyzer Measurement Parameters:
Broadband: LXY, LXYmax, LXYmin, LXeq, LXpeak, Lavg, LC-LA, LXIeq,
Octave Band & 1/3 Octave Band: LXY, LXeq, LXYmax.
CEL-631 and CEL-633 models add storage of 5x Ln in broadband and octave band modes
Cel-632 and CEL-633 models add time history data storage
Can record characteristics over time
(Additionally: CEL-633 can also record 5x Ln )
X represents frequency weighting A, C, Z; Y represents time weighting F, S, I. All weightings are recorded simultaneously




Instrument Q&A



  • What is the maximum dB measurement of the UK Casella CEL-630 Recording Octave Band Noise Analyzer?



    Hello, the maximum measurement of the UK Casella CEL-630 sound level meter is 140dB.






WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio Tester、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us