LWJ 2010 Insulating Boots and Gloves Withstand Voltage Test Device |
Darui Electric recommends
This device is specialized equipment for batch testing of insulating boots and gloves. It can also be used to test safety tools, such as insulating rods, insulating screwdrivers, insulating pads, etc. It is designed and produced by our company based on the test requirements for insulating boots and gloves and in compliance with the opinions of our users. This product effectively solves the problem of non-standard testing in the past, improves work efficiency, and ensures work safety. It is an ideal special device for insulating shoes (gloves).
This device adopts advanced microelectronics processing technology. All processes can be set in advance, with a full Chinese interface and simple and clear operation. After setting all test items, the test is automatically performed without manual intervention.
Technical Specifications
1. Input Voltage: AC220V/50Hz
2. Output Voltage: 0-100kV
3. Capacity: 10kVA
4. Number of Tested Items: 6 pieces at a time
5. Measurement Data: Can display and print the voltage value and leakage current value of each tested item
6. Overcurrent protection; overvoltage protection; custom time, voltage, and leakage current values
7. LCD display, full Chinese menu operation, with printing
8. Measurement Accuracy: Voltage ±2% (±3 digits), Current ±2% (±3 digits)

Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.